DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V

٦٧٤٫٠٠ E£
والشحن مجاناً

DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V

  • العلامة التجارية: Unbranded

DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٬٥٩٩٫٠٠ E£
السعر: ٦٧٤٫٠٠ E£
أنت توفر: ٩٢٥٫٠٠ E£ (57%)
البائع:
٦٧٤٫٠٠ E£
والشحن مجاناً

في المخزون

سياسة الإرجاع لمدة 14 يوما

طرق الدفع:

الوصف

DC Current Detection Module Relay Switch Sensor Digital Display Motor Controller 12V

Features 1.Control Module: When the current is too large or too small, the relay switch will control line to connect and disconnect, or give a signal. 2.Detection Range: Can conveniently detect DC 7‑30V current between 0‑10A, and the detection voltage is equal to the input power voltage. 3.Practical Using: Comes with error calibration function, and the display can also be turned off for a long time to reduce power consumption. 4.High Accuracy: The current detection module has a high accuracy up to 0.01A, which ensures small error for easier and more efficient work. 5.Easy Operation: Digital display enables a clear view to the work status, and the simple operation will help to prevent the stalling as well. Specification Item Type: DC Current Detection Module Product Model: YYI-2. When the detection current is too large or too small, the control relay switch will control the circuit to be on or off, or give a signal; Detection Range: DC 7-30v current between 0-10A, the detection voltage is equal to the input power voltage; Detection Accuracy: 0.01A (10mA) Error Calibration: With error calibration function, and the display can be turned off for a long time to reduce power consumption; Standby Current: About 20mA; Relay Output: Can control the on and off of DC lines within 10A; Function Description: 1. P-11: When the measured current is greater than I1, the relay is closed; when the measured current is less than I1 again, the relay is disconnected; 2. P-12: When the measured current is greater than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 3. P-21: When the measured current is greater than I2, the relay is closed; when the measured current is less than I1, the relay is disconnected; 4. P-22: When the measured current is greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 5. P-31: When the measured current is less than I1, the relay is closed; when the current is greater than I2, the relay is disconnected; 6. P-32: When the measured current is less than I1, the relay is closed; and it will always stay closed until the circuit board is powered off; 7. P-41: When the measured current is between I1 and I2, the relay is closed, otherwise the relay is disconnected; 8. P-42: When the measured current is between I1 and I2, the relay is closed; and it will always stay closed until the circuit board is powered off; 9. P-51: When the measured current is less than I1 or greater than I2, the relay is closed, otherwise the relay is disconnected; 10. P-52: When the measured current is less than I1 or greater than I2, the relay is closed; and it will always stay closed until the circuit board is powered off; Setting Instructions: 1. Power on to display the measured current; (if the measured current terminal is suspended, the number of digital display is normal); 2. The first time K1 is pressed, it takes more than 1 second to be effective to prevent false triggering. The screen displays: P 11: K2 adjustment mode, K3 adjustment function; 3. Press K1 for the second time, the screen flashes: 0.05 means that the value of the threshold I1 is 0.05A; K2 sets I1 plus, K3 sets I1 minus; 4. Press K1 for the third time, the screen flashes: 0.10 means the value of the threshold I2 is 0.1A; K2 sets I2 plus, K3 sets I2 minus; 5. Press K1 for the fourth time, the screen displays the measured current; it means it enters the standby state; 6. In standby mode, long press K2 or K3 to fine tune the measured current error. Package List 1 x DC Current Detection Module
  • هوية Fruugo: 360511117-783957203
  • EAN: 9582361490580

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الاثنين 12 يناير 2026 – الجمعة 16 يناير 2026 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Shenzhenshi Desheng Wangluo Keji Youxian Gongsi
  • Shenzhenshi Desheng Wangluo Keji Youxian Gongsi
  • NO,606-23-220,MeinianGuojiGuangChangZhaoshangJiedaoNanHaidadao yixiShenzhenGuangdong
  • Shenzhen
  • CN
  • 518000
  • GoodLuck856@163.com
  • 8613164761511

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • SINO-SEAR GmbH
  • SINO-SEAR GmbH
  • Feuerbachstrasse 11, 14471 Potsdam, Germany
  • Potsdam
  • DE
  • 14471
  • info@sino-sear.com
  • 4933195130908