6 in 1 Multifunction Digital Meter YB5140DM-Z AC 0~100A 130~500V

١٬١٤٩٫٠٠ E£
والشحن مجاناً

6 in 1 Multifunction Digital Meter YB5140DM-Z AC 0~100A 130~500V

  • العلامة التجارية: Unbranded

6 in 1 Multifunction Digital Meter YB5140DM-Z AC 0~100A 130~500V

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٬٤٩٩٫٠٠ E£
السعر: ١٬١٤٩٫٠٠ E£
أنت توفر: ٣٥٠٫٠٠ E£ (23%)
البائع:
١٬١٤٩٫٠٠ E£
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Features: Measurement of electrical parameters: AC voltage/ current/ active power/ frequency/ power factor/ energy,6 in 1. Power zero-clearing mode: key zero-clearing, automatic zero-clearing. Display Type: LCD display, blue backlight;-Multi-screen display, "7 kinds of display modes" optional. Blue backlight brightness adjustable: highlight, low light, not bright. The voltage, current error and other options can be calibrated by the button itself. Displays updated values for different working environments. display accuracy can be set:3-bit,4-bit; applicable to different requirements power down data saving function. The AC voltage, current, power and electric energy are all designed by automatic shift of decimal point has the functions of voltage, current, power upper and lower limit alarm and timeout alarm, besides the buzzer alarm, there is the optical coupling alarm output control function. Specification : Measurement range ACV130-500V; ACA0-100A Resolution When the voltage is less than 100V, the resolution is 0.01 V; when the voltage is greater than 100V, the resolution is 0.1V The resolution of current less than 10A is 0.001 A;Over 10A, the resolution is 0.01 A Measurement accuracy 0.5% ± 2 digit s Measurement speed about 2 times per second Active power 0-9999 KW Frequency 45.00-65.00 Hz Power Factor 0.000-1.000 Power 0.000-9999 KWh Operating temperature -10 ~ + 50 ℃ Working humidity 10 ~ 80% (without condensation) Working pressure 80 ~ 106 kPa Package List: 1 * Multi-function intelligent watch head 1 * Mutual inductance coil Note: As different computers display colors differently, the color of the actual item may vary slightly from the above images. Operation Setting Manual: Code Nmae Description 1-CU Calibrate Voltage Calibration voltage error 2-CA Calivrate Current Calibration current error 3-SP Display Speed S: Standard speed update display value L: Slow update display value F: Fast update display value 4-En Power Option REA: Resumption After the power, if there is no electricity generation, will always show the power before the power supply accumulated;When the power generation, the display screen flash two times, before the power cut down the accumulated energy value will be automatically zero, and from the beginning of the accumulation; CLE: Accumulated electric power manual zero clearing ACC: After the power on, the accumulated electric energy value will not automatically clear the zero, has been accumulated 5-ty Alarm Type S: Semi-automatic, as long as the alarm start, regardless of the value after the start of no change, will always alarm, unless someone for any key to remove the alarm will stop A: Full automatic, when the alarm start-up value back within the scope, will automatically remove the alarm 6-oU Over Voltage Value Set voltage alarm upper limit 7-LU Voltage Floor Set Voltage Alarm Lower Limit 8-oA Over Current Value Set current alarm upper limit 9-LA Current Floor Set Current Alarm Lower Limit A-oP Over Power Value Set power alarm upper limit b-LP Power Floor Set Power Alarm Lower Limit C-ot Over Time Alarm Countdown alarm function,00:00-99 hours 59 minutes;Time-out alarm and upper and lower limits alarm can only be double-checked d-on Default Optical coupling state H: No start alarm time coupling output for high-level, that is, open-circuit state, post-start output low-level L: No start alarm time coupling output for low level, that is, short circuit state, post start output high level E-St Starting Delay 0-9999 seconds, instrument never alarm state to alarm state switch output delay time;This start-up alarm will be ignored when the alarm duration is <E-St n-Et End Delay 0-9999 seconds, the instrument from the alarm state to the unalarm state to switch the output delay time;When the release alarm duration is <n-Et, the release alarm will be ignored F-dS Setting Display Digits 4: Voltage, current, frequency, power factor display 4 digit 3: Voltage, current, frequency, power factor display 3 digit H-rS Factory Data Reset N: Do not restore factory value Y: All settings restore factory value
  • هوية Fruugo: 414427985-875506404
  • EAN: 7908770383763

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Warning: Please read the product instructions carefully before use to ensure correct use.
رقم سري: 7908770383763

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الاثنين 06 أكتوبر 2025 – الاثنين 13 أكتوبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • Wuhan Jinxingkai Network Technology Co., Ltd.
  • No. 1-1, Door 57
  • Shihua Village
  • Qingshan District
  • Wuhan
  • CN
  • 430000
  • goldxinks@163.com
  • 0086 17786498762
  • https://shop01473o1711614.1688.com/page/creditdetail.htm?spm=a261y.7663282.shopNavigation.1.6310755czE9SFQ

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795