A830L Multimeter Handheld High Precision Multifunction Portable Digital Multimeter Ammeter Voltmeter Measuring Table Combination
A830L Multimeter Handheld High Precision Multifunction Portable Digital Multimeter Ammeter Voltmeter Measuring Table Combination
• High Precision Measurement :
The A830L Multimeter offers high precision measurement, ensuring accurate readings for voltage, current, and resistance.
• Multifunctional :
This digital multimeter is not just an ammeter or voltmeter, but also a multifunctional tool that can measure capacitance, frequency, and temperature.
• Portable and Handheld :
The A830L Multimeter is designed to be portable and handheld, making it easy to carry around and use on-the-go.
• LCD Display :
The digital display on the A830L Multimeter makes it easy to read and interpret measurements, even in low light conditions.
Multifunctional Handheld Digital Multimeter
Maximum: 135 x 67 x 33mmm
Color: orange black
DC current range: 200u-2m-20m-200m-10A ±1.8%
DC voltage range: 200mV--2-20-200-600V ± 0.5%
AC current range: 200V-600V ±1.0%
Geo de resistentie: 200-2k-200k-200k--2MΩ1,0%
Range capacity: 1MΩ
Maximum display: 1999
Certification and standard: CE
Battery type: 6F22 type 9V battery (battery not included)
Notice:
Due to the different monitor and light effect, the actual color of the item might be slightly different from the color showed on the pictures. Thank you!
Please allow 1-2cm measuring deviation due to manual measurement.
OPERATING INSTRUCTIONSDC
VOLTAGEMEASUREMENT
1 . Connect the red test lead to the " V Q MA " jack andthe black lead to the
“
COM
”
jack.
2.
Set rotary switch at desired DCV position . If thevoltage to be measured is not known beforehand , setrange switch at the highest range position and thenreduce ti until satisfactory resolution is obtained.
3 . Connect test leads across the source or load beingmeasured.
4.Read voltage value on the LCD display along with thepolarity of the red lead connection.
CURRENT MEASUREMENT
1 . Connect the red test lead to the " MA " jack andthe black test lead to " COM " jack ( Formeasurements between 200MA and 20A . remove redlead to " 20A " jack .
2 . Set the rotary switch at desired DCA position
3 . Open the circuit in which the current is to be measured and connect test leads in series with the circuit.
4 . Read current value on LCD display along with thepolarity of red lead connection.
AC VOLTAGE MEASUREMENT
1.Connect the red test lead to " V . n " jack and theblack testlead to the COM " jack.
2 . Set the rotary switch at desired ACV position.
3 . Connect test leads across the source or load beingmeasured.
4 . Read voltage value on the LCD diaplay.
RESISTANCE MEASUREMENT
1 . Connect the red test lead to " V . a " jack and blacktest lead to the " COM " jack . ( The polarity of red leadis positive " + " ).
2 . Set the rotary switch at desired " Q " range position .
3 . Connect test leads across the resistor to be measuredand read LCD diaplay.
4 . If the resistance being measured is connected to acircuit , turn off power and discharge all capacitorsbefore applying test probes .
DIODE TEST
1 . Connect the red test lead to " V . Q " jack andthe blacktest lead to the " COM " jack ( The polarityof red leadis positive " + " , )
2 . Set the rotary switch at " - + " position.
3 . Connect the red test lead to the anode of the diode tobe tested and the black test lead to the cathode of thediode . The approx , forward voltage drop of the diodewill be displayed . If the connection is reversed . Onlyfiaure " 1 " will be shown.
TRANSISTOR TEST
1 . Setthe rotary switch at " HFE " position
2 . Determine whether the transistor under testing is NPNor PNP and locate the emitter , base and collectorleads . Insert the leads into proper holes ofthe HFEsocket on the front panel
3 . Read the approximate HFE value at the test conditionof base current 10 UA and Vce 3V.
NOTE :
To avoid electrical shock . remove test leads from measurementcrcuits before testing a transistor .
AUDIBLE CONTINUITY TEST
1 . Connect red test lead to " VO" blackest lead to
“
COM
”
.
2 . Set range swith to " . ) ) " Position.
3 . Connect test leads to two points of circuit to be tested . Ifcontinuity exists , built-in buzzer will sound.
MEASURING TEMPERATURE
1 . Set the rotary switch at TEMP Position and theLCD display will show the current environmenttemperature.
2 . Connect the K type thermoelectric couple to vQ MAC " and " COM " jacks .
3 . The display will read Temperature Vatuet.
MEASURING FREQUENCY
1 . Connect the black test lead to the COM jack and thered test lead to the Va Hz jack .
2 . Set the rotary switch at KHZ position and connect testleads across the source or load under measruement .
NOTE :
1 . Reading is possible at input voltages above 10vrmsbut the accuracy is not guaranteed.
2 . In noisy environment , it is preferable to use shieldcable for measuring small signal.
MEASURING CAPACITANCE
1 . Set the rotary switch at desired F position .
2 . Before inserting capacitor under measurement intocapacitance testing socket . be sure that the capacitor hasbeen discharged fully .
3 . When measuri
-
هوية Fruugo:
463038084-974287897
-
EAN:
7992701888816
معلومات سلامة المنتج
يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه
يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.
ملصقات سلامة المنتج
تحذيرات السلامة:
WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
مكونات:
Octinoxate 3.3522%
رقم جزء الشركة المصنعة:
ZW300872
رقم الموديل:
ZW858112
رقم سري:
ZW003352
رقم الدفعة:
ZW001432