RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

٧٤٩٫٠٠ E£
والشحن مجاناً

RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

  • العلامة التجارية: Unbranded

RD72-DC-12V Infinite Cycle ON OFF Relay Module Trigger Delay Switch Infinite Loop Relay

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٬٣٤٩٫٠٠ E£
السعر: ٧٤٩٫٠٠ E£
أنت توفر: ٦٠٠٫٠٠ E£ (44%)
البائع:
٧٤٩٫٠٠ E£
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Features 1、With start / stop function, the module enters infinite cycle mode after starting, and the relay works on and off according to the set time. 2、Infinite-cycle power-on and power-off modules, the delay time can be adjusted separately, the longest delay can be 1000min. 3、Low power consumption of the control board, less than 1W. 4、Start external wiring button: Passive switch input. The green light turns on after starting, and stays in the red light after stopping. 5、The button is required to be unlocked (ie self-resetting). It can also be connected to external voltage signals. When the voltage is lower than 2V, it is low level. When the voltage is higher than 2V, it is high level. The maximum input should not exceed 30V. Specification Item Type: Cyclic On-Off Relay Module Power Consumption: <1.0W Output: Passive output (ie dry contact), a group of normally open + normally closed. Do not exceed 10A. Life: 100,000 operations Time Range: 0.5 seconds-1000 minutes Time Accuracy: the maximum value of the range * 0.001, that is, 1000-level resolution Start external wiring button: Passive switch input. The green light turns on after starting, and stays in the red light after stopping. Wiring Terminal: <-- DC + Module power supply positive input <-- DC - Module power supply negative input --> NO Normally open contact wiring terminal --> COM Common contact wiring terminal of relay --> NO Normally closed contact terminal of the relay, generally not connected. Instructions: Time can be set in both power-on and power-off states Please refer to the detailed explanation of the actual photos and pictures later to understand the operation method more intuitively. 1. ON time setting: The potentiometer under the RUN TIME mark adjusts the time, clockwise to increase the duration, and counterclockwise to shorten the duration. The left side of the down-dial switch of the potentiometer is the time range setting. The adjustable range of the adjustable resistor is 0-100 after dialing down; the range of 0-1000 after dialing up. The right side of the down-dial switch of the potentiometer is set in units. Dial down to Sec. For seconds; dial up to Min. For minutes. 2. OFF duration setting: The potentiometer under the OFF TIME mark adjusts the time, clockwise to increase the duration, and counterclockwise to shorten the duration. The left side of the down-dial switch of the potentiometer is the time range setting. The adjustable range of the adjustable resistor is 0-100 after dialing down; the range of 0-1000 after dialing up. The right side of the down-dial switch of the potentiometer is set in units. Dial down to Sec. For seconds; dial up to Min. For minutes. 3. Start button: Connect the self-reset button, press it once, switch to green light, indicating running status, the module will automatically work according to the set running time and stop time, infinite cycle. At this time, press the start button again, the module will switch to a red light, indicating that it is in a stopped state. 4. Example of time setting: Requirements: 20 seconds on, 30 minutes off, infinite loop. Settings: (1) Dial down the running time range to 0-100; (2) Dial down the running time unit to seconds; (3) Rotate the running time potentiometer to 20 position, that is, 20/100 position from the left; (4) Dial down the stop time range to 0-100; (5) Dial up the stop time unit to minute; (6) Rotate the stop time potentiometer to 30 position, that is, 30/100 position from the left; Operating mode: (1) RD72-DC-A / Standard: Press the start button once to start the cycle, and then press the start button again to stop the work. The starting cycle mode is: on--off--on--off-- (2) RD72-DC-AS / Enable version: Press and hold the button to start the infinite loop, release the button to stop the loop and jump to the disconnected state. The starting cycle mode is: on--off--on--off-- Package List 1 x Relay Module
  • هوية Fruugo: 271670869-602232657
  • EAN: 9308869142222

معلومات سلامة المنتج

يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

ملصقات سلامة المنتج

CE Mark
تحذيرات السلامة: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الاثنين 20 أكتوبر 2025 – الجمعة 24 أكتوبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة